Repair planning for an aging metal roof
The November 5 proposal brings together an annotated roof plan, close-up roof photographs and interior observations to locate the work.
Converting the translucent panel areas
The proposed scope removes 54 translucent panels on the right side of the main roof and covers those openings with solid PBR metal panels. Solid panels would replace the daylight previously admitted through those locations.
Flashing and fastener details
The package also addresses transition flashing, closures, rake-trim corrections, one exhaust-vent seal and miscellaneous missing fasteners. The roof plan and photographs show how these repairs relate to the existing building.